臺(tái)灣標(biāo)準(zhǔn)電機(jī)SEW儀器儀表--2820 EL ELCB Testers Up To 1000mA


        
     
    2820 EL   ELCB Testers
    Up To 1000mA  
    2820 EL
    FEATURES
     
     Operating voltage 100-450V L-E.
     Rated current 999mA, at 317V AC/50Hz.
     Checks ELCB trip time and trip point (sensitivity).
     Auto-Off/Auto-Ranging.
     Phase angle selection (0 degree / 180 degree).
     Indicates tripping phase angle.
     Impact resistant enclosure.
     Over temperature shut-down.
     Transient protection.
     Suitable for heavy industrial use.
     Fused.
     , -1 CAT III 450V.
     OPERATING PRINCIPLES
     EARTH LEAKAGE TESTS
     The testers may be used to check the trip point (Test 1) of the ECLB or the trip time (Test 2). Test 1 is normally used on instantaneous ELCBs while Test 2 is normally used on inverse and fixed time-delay ELCBs.
     TEST PROCEDURE
     Test 1 - instantaneous ELCBs A ramp current, increasing at approximately 12 mA/s is introduced between L and E and the point at which the ELCB trips is recorded. To save time and reduce energy dissipation, the starting point of the ramp may be selected.
     Test 2 - inverse and fixed time delay ELCBs. Aconstant current is selected and injected between L-E and the tripping time is recorded.
    SPECIFICATIONS
     
    Trip Current-Range 0-1 A at 317V (Auto-Range Programmable)
    Trip Current-Resolution 1mA
    Operating Voltage (L-E) 100-450V
    Phase Angle Setting 0 degree and 180 degree selectable
    Timer-Max 99.999s
    Timer-Resolution 1mS
    Typical Accuracy
    Trip-Current +/- 1%rdg +/-1mA
    Trip-Time +/- 1%rdg +/-1dgt
    Voltage +/- 3%rdg +/-1dgt
    Operating-Temperature-Humidity -10 degree C to + 40 degree C, 80% max relative humidity
    Power Source 1.5V (AA) x 8 batteries
    Dimensions 170(L) x 120(W) x 95(D) mm
    Weight Approx. 800g (battery included)
    Accessories Test leads
    Shoulder belt
    Instruction manual
    Batteries
    特 點(diǎn)
    ● 微處理器系統(tǒng)控制設(shè)計(jì)。
    ● 操作電壓110-450V(L-E)。
    ● 檢查核對(duì)斷路器跳脫時(shí)間和跳脫電流。
    ● 可選擇相位(0度和180度)。
    ● 自動(dòng)換檔。
    ● 自動(dòng)關(guān)機(jī)。
    ● 過(guò)熱保護(hù)。
    ● 可供重工業(yè)設(shè)備量測(cè)。
    ● 保險(xiǎn)絲保護(hù)。
    ● 符合 -1 CAT Ⅲ 450V
    規(guī) 格 (23°C±5°C <80%R.H.)
    跳脫電流檔位 0-1A在317V時(shí)(自動(dòng)換檔)
    跳脫電流解析度 1mA
    操作電壓(L-E) 100 - 450V
    相位選擇 0°與180°
    測(cè)試Z長(zhǎng)時(shí)間 99.999秒
    時(shí)間解析度 1ms
    跳脫電流準(zhǔn)確度 ±(1%讀值+1mA)
    跳脫時(shí)間準(zhǔn)確度 ±(1%讀值+1位數(shù))
    電壓準(zhǔn)確度 ±(3%讀值+1位數(shù))
    操作溫濕度 -10°C-40°C 80%
    外形尺寸 170(長(zhǎng))×120(寬)×95(高)mm
    重量 約800g(含電池)
    使用電池 1.5V(AA)×8(顆)