HPF HIGH PASS FILTER
Description
HPF filters are specially designed to remove harmonics from the current absorbed by 6 pulse power converters, such as frequency converters for motors, UPS, welding equipment, etc. They are essentially passive filters based on a series parallel combination of inductance and capacitors. (Main function is to filter the 5th and 7th current harmonic and to decrease the level of the 11th and 13th current harmonics). With these HPF filters we will be able to get a reduction of the THD (I) level higher than a simple input reactor reduction, decreasing THD (I) to values below 8%. At full load conditions the THD (I) becomes lower than 5%.
Options
Kit regulación sobre-compensación/Overcorrection regulating Kit
Kit de medida/Measuring kit
Technical Characteristics
Tensión nominal/Rated voltage .........................................................................400 ~ 480 V
Frecuencia/Frequency .........................................................................................50/60 Hz
Corriente RMS de carga (Ic)/RMS load current (Ic) ......................................4 ... 1000 A
Máx. sobrecarga /Max. ooverload ..........................................................................................1min. a 1,5 Ic
Corriente RMS filtrado (If)/Filtered RMS current (If)........................................1.6 ... 72 A
THD residual/THD residual current ...................................................................Aprox. 8%
Caída de tensión a In/Voltage drop at In................................ ......................< 2%
Construcción/Construction ...................................................................................Armario metálico/Metal cabinet
Grado de protección/Protection degree ........................................................
Color/Colour .........................................................................................................Gris RAL 7035
Instalación/Installation .........................................................................................Interior/Indoor
Montage/Assembly ...............................................................................................Tipo A/B: Mural, Tipo C/D: Sobre suelo
A/B type: Wall mounting, C/D type: Floor mounting
Normas/Standards ..............................................................................................

Part number RMS load current(A) Filtered RMS
current (A)
Voltage(V) Frequency (Hz) Cabinet Price()
50 Hz  
HPF140009 9 3.6 400/415 50 A On request
HPF140016 16 6.4 400/415 50 A
HPF240022 22 8.8 400/415 50 A
HPF240032 32 12.8 400/415 50 A
HPF240040 40 16 400/415 50 A
HPF240047 47 18.8 400/415 50 B
HPF240054 54 21.6 400/415 50 B
HPF340064 64 25.6 400/415 50 B
HPF340076 76 30.4 400/415 50 B
HPF340090 90 36 400/415 50 C
HPF340110 110 44 400/415 50 C
HPF440150 150 60 400/415 50 C
HPF440180 180 72 400/415 50 C
  ... 400       D
             
60 Hz  
HPF146009Z 9 3.6 460/480 60 A On request
HPF146016Z 16 6.4 460/480 60 A
HPF246022Z 22 8.8 460/480 60 A
HPF246032Z 32 12.8 460/480 60 A
HPF246040Z 40 16 460/480 60 A
HPF246047Z 47 18.8 460/480 60 B
HPF246054Z 54 21.6 460/480 60 B
HPF346064Z 64 25.6 460/480 60 B
HPF346076Z 76 30.4 460/480 60 B
HPF346090Z 90 36 460/480 60 C
HPF346110Z 110 44 460/480 60 C
HPF446150Z 150 60 460/480 60 C
HPF446180Z 180 72 460/480 60 C
  ... 400       D

Other current, voltages and frequencies available on request. Loads which need an instantaneus correction available on request.

Harmonic filters HAF, HPF
HAF ABSORPTION FILTER HPF140004 HPF146004Z HPF140009 HPF146009Z HPF140016 HPF146016Z HPF240022 HPF246022Z HPF240032 HPF246032Z HPF240040 HPF246040Z HPF240047 HPF246047Z HPF240054 HPF246054Z HPF340064 HPF346064Z HPF340076 HPF346076Z HPF340090 HPF346090Z HPF340110 HPF346110Z HPF440150 HPF446150Z HPF440180 HPF446180Z

Harmonic Filters
These filters are used when the main objective is not the reactive power compensation at the fundamental frequency, but to reduce the harmonic distortion in the supply system.
Among the problems caused by harmonics and which may make their suppression necessary, are the following:
Interferences in telecommunications.
Distortion on the mains voltage.
Disturbances in electronic systems.
Erratic operation of control and protection relays .
Failures in transformers and motors, due to overheating caused by losses on the core.
Overheating of protective fuses to the point where a minor spike on the line causes them to blow.
It should be pointed out that the impedance of all the filters is capacitive below its tuning frequency, whereby they also contribute, even if in a small scale, to the reactive power compensation at the fundamental frequency.
Installation of filters produces a modification on the topology of the electrical supply system. For this reason, the design of filters must be done with regard to an accurate analysis and study of the whole system.
According to the application, there are different types of filters:
3rd harmonic filter HBF-T
Isolation filter
Absortion filter HAF
High pass filter HPF
Active filter SINAF 2.0

  • 電力電容器Power capacitors

  • 諧波濾波器Harmonic filters
  • 電容器柜Automatic Banks

  • 返回西班牙LIFASA電容器首頁
  • 防護濾波器Protection filters
  • 無功功率控制器Reactive power controllers
  • 附件Accessories and auxiliary
  • 電機和照明電容器MOTOR AND LIGHTING CAPACITORS